The MININEPH™PLUS is a small, stylish semi-automated nephelometer. It is easy to use and enables laboratories to offer a cost efficient service for lower volume specialist protein assays.
Freelite® serum free light chain assays
- The only semi-automated nephelometer able to run Freelite®
- Automatic antigen excess check for Freelite® assay.
Simple to use with on-screen instructions for running assays
- Interface is available in 6 different languages which are displayed on the easy to view back-lit display.
Integral and Heated Single Button Electronic Pipette
- Ergonomic pipette requires no volume input, further increasing the simplicity of the system.
Fail Safe Assay Start Mechanism
- The assay starts when the pipette is activated, reducing the chance of false starts due to reagent sensing errors, thus saving time and reagents whilst increasing confidence in results.
Automatic Assay Blanking & Mixing
- Increases the accuracy and precision of results.
Hand Held Barcode Reader
- Negates transcription errors whilst speeding up sample identification input.
MININEPH™PLUS & Kits manufactured by Binding Site
- Binding Site supplies everything you need to run the MININEPH™PLUS. The systems and assays are developed, optimised and validated together, ensuring excellent system and assay quality.
User Prepared Chemistries
- Also ideal for research laboratories, user prepared chemistries allows the user to develop new assays.
Measurement Method
- Endpoint nephelometry
Throughput
- Up to 30 tests per hour (Freelite® 12 tests per hour)
Reaction module
- Laser diode (670nm, <1mW-Class II) light source
- 45°C or 30°C ± 0.5°C reaction temperature
Reagent delivery
- Integrated Pipette with pre-set dispensing volume
- In-line buffer with pre-heating to reaction temperature
Input
- Membrane keypad
- Pre-programmed magnetic swipe cards
- Hand held sample barcode reader (optional)
Output
- 2 x 16 character alphanumeric LCD display
- Thermal serial printer (optional)
Dimensions
- Height 360mm x Width 240mm x Depth 280mm
- Weight 5.7kg (including pipette)
Power requirements
- 90 - 250V AC
- 50 - 60Hz
- 80VA
| Description |
Pack |
Code |
| MININEPH™PLUS | 1 | AD500 |
| On-Board Buffer |
1x45 mL |
SN107.1 SN107.4 |
| Accessory Pack Cuvettes, Stirring bars, Sample Diluent |
200 | ZK500.R |
| MININEPH™PLUS Printer (optional) | 1 | AP1310DPKIT63 |
| MININEPH™PLUS Thermal Printer Paper | 20 | AO5856TPR1 |
| Hand Held Barcode Reader (optional) | 1 | AD500.2 |
|
Description
|
Pack
|
Code
|
|
Freelite® Kappa MININEPH™PLUS kit
Range 3.02 - 72.4 mg/L |
2 x 15 test
|
VK016
|
|
Freelite® Lambda MININEPH™PLUS kit
Range 4.91 - 98.3 mg/L |
2 x 15 test
|
VK018
|
| IgG MININEPH™ kit Range 2.0 - 25 g/L Sensitivity 0.9 g/L |
50 test | ZK004.R |
|
IgG-LL**
Range: 0.01 - 0.168 g/L
|
50 test | ZK004.LL |
| IgA MININEPH™ kit Range 0.37 - 5.94 g/L Sensitivity 0.17 g/L |
50 test | ZK010.R |
| IgM MININEPH™ kit Range 0.25 - 4 g/L Sensitivity 0.25 g/L |
50 test | ZK012.R |
| IgG1 MININEPH™ kit Range 1440 - 23000 mg/L |
10 test | ZK006.R |
| IgG2 MININEPH™ kit Range 802 - 9625 mg/L |
10 test | ZK007.R |
| IgG3 MININEPH™ kit Range 76 - 1210 mg/L |
2 x 5 test | ZK008.L.R |
| IgG4 MININEPH™ kit Range 53 - 847 mg/L |
2 x 5 test | ZK009.L.R |
| Albumin Range: 7.1 - 114 g/L |
25 tests | ZK032.R |
| α-1- Antitrypsin Range: 0.35 - 5.6 g/L |
25 tests | ZK034.R |
| Apolipoprotein A1 Range: 0.3 - 2.4 g/L |
25 tests | ZK085.R |
| Apolipoprotein B Range: 0.37 - 5.85 g/L |
25 tests | ZK086.R |
| β2 Microglobulin Latex Range: 0.75 - 12 mg/L |
2 x 10 tests | ZK043.L.R |
|
C1 Inactivator** |
25 tests | ZK019.R |
| Caeruloplasmin Range: 0.14 - 2.26 g/L |
25 tests | ZK045.R |
|
C3
Range: 0.28 - 4.44 g/L
|
50 tests |
ZK023.R
|
|
C4
Range: 0.08 - 1.23 g/L
|
50 tests |
ZK025.R
|
| CRP Latex Range: 3.5 - 112 mg/L (1/40) 0.4 - 14 mg/L (1/5) |
2 x 25 tests | ZK044.L.R |
| Haptoglobin Range: 0.24 - 3.89 g/L |
25 tests | ZK058.R |
| Microalbumin Range: 15 - 235 mg/L |
25 tests | ZK032.U.R |
| Prealbumin (Transthyretin) Range: 0.06 - 0.93 g/L |
25 tests | ZK066.R |
| Transferrin Range: 0.4 - 6.4 g/L |
25 tests | ZK070.R |
| ASO Latex Range: 60 - 960 IU/mL |
2 x 25 tests | ZK189.L.R |
| RF Latex Range: 31 - 500 IU/mL (1/40) 8.6 - 137.5 IU/mL (1/11) |
2 x 25 tests | ZK151.L.R |
MININEPH™ assays can be run on both the MININEPHplus™ and MININEPH analysers.
We have a comprehensive assay development programme with all MININEPH™ assays expected to be available on the MININEPH™PLUS by the end of 2010.







MININEPH™PLUS Product Specification
MININEPH™PLUS Product Specification