Radial Immunodiffusion (RID) Kits

Thousands of laboratories world-wide rely upon a method of protein quantitation that has remained a "Gold Standard" for over 25 years. Radial immunodiffusion (RID), which is based on the complexing of antigen and antibody to produce a visible precipitin ring, is still a reference method to which new methods are compared.

RID remains a reliable laboratory diagnostic test method and is particularly useful for difficult samples e.g. that are turbid and for which other methods are inappropriate.

The BINDARID™ range of test kits, based on conventional RID technology, is suitable for measuring protein concentrations down to approximately 5mg/mL.

NANORID™ kits use a novel patented technology to enable accurate quantitation of very low concentrations of protein in serum, urine, cerebrospinal fluid and other biological materials. Sensitivities as low as 0.15 mg/mL can be achieved.

Binding Site has a wide range of radial immunodiffusion assays:

SpecificationsRID kit for immunoglobulins

14 pre-cut wells per plate

Single high calibrator or calibration set (high, medium, low)

10 - fold measuring range

Plates readable by RID reference table (Mancini), Complete diffusion (Mancini) or Incomplete diffusion (Fahey and McKelvey)

RID assays for Human Complement Proteins

The complement system is a complex series of proteins that act as a cascade. They react in the sequence C1q, C1r, C1s, C4, C2, C3, C5, C6, C7, C8, C9; many requiring proteolytic cleavage to become active. The cascade is activated either via the Classical Pathway, the Alternative Pathway or the Lectin Pathway.

Complement is involved in initiating an inflammatory response and destroying certain bacteria and viruses. Complement proteins are assayed to measure complement consumption and to diagnose inherited deficiencies of cascade components.

Assays for Investigation of Complement Function

Total Haemolytic Complement (THC) and Alternative Pathway Haemolytic Complement (APHC) kits are effective screening assays to aid in the identification of complement deficiency.

The Total Haemolytic Complement kit is primarily designed to detect deficiencies of the Classical Complement Pathway and the terminal sequence (C3-C9) components, whereas the Alternative Pathway Haemolytic Complement kit is designed to measure the activity of the Alternative Complement Pathway.

 

DescriptionPackCode

Total Haemolytic

Complement kit

 

3 plate kit

2 plate kit

1 plate kit

RC001.3

RC001.2

RC001.1

Alternative Pathway

Haemolytic Complement kit*

3 plate kit

1 plate kit

RC003.3

RC003.1

C1 Inactivator

Functional activity kit**

C1 Inactivator

Functional activity COMBI kit**

Combi kit contains 2 functional activity plates and 1 antigenic quantitation plate.

3 plate kit

 

3 plate kit

RC002.3

 

RK019

RID Assays for Investigation of Complement Deficiency

Binding Site also provides RID kits to detect and quantify individual components or factors in the complement cascade. 1 plate kits are available for a number of specificities, enabling small numbers of samples to be run economically.

DescriptionMeasuring Range (mg/L)PackCode
C1 Inactivator - NL45 - 4503 plate kitRN019.3
C1q - NL23 - 230#3 plate kitRN020.3
C2 - NL***3.6 - 363 plate kitRN022.3
C3 - NL155 - 15503 plate kitRN023.3
C4 - NL58 - 5803 plate kitRN025.3
C4 - Binding Protein - NL*50 - 5003 plate kitRN026.3
C5 - NL20 - 2003 plate kitRN027.3

C6 - NL*

 

12 - 120

 

3 plate kit

1 plate kit

RN102.3

RN102.1

C7 - NL*

 

22 - 110

 

3 plate kit

1 plate kit

RN103.3

RN103.1

C8 - NL*

 

20 - 200

3 plate kit

1 plate kit

RN089.3

RN089.1

C9 - NL

50 - 500

 

3 plate kit

1 plate kit

RN028.3

RN028.1

Factor B - NL**45 - 4503 plate kitRN029.3

Factor H (β 1H) - NL*

 

70 - 700

 

3 plate kit

1 plate kit

RN030.3

RN030.1

Factor I - NL*7 - 701 plate kitRN031.1

# Diluted sample applied - assay range may be extended using undiluted sample.

* Research use only

** Not available in the USA

*** In the USA for research use only

Human Immunoglobulin Kits

DescriptionMeasuring Range (mg/L)PackCode
IgG - NL2250 - 225003 plate kitRN004.3
IgG - ML*18 - 1803 plate kitRL004.3
nanorid- IgG - UL*0.45 - 4.53 plate kitGL004.3
IgG1 Subclass - SD1400 - 14000#3 plate kitRN106.3
IgG2 Subclass - SD800 - 8000#3 plate kitRN107.3
IgG3 Subclass - SD120 - 12003 plate kitRN108.3
IgG4 Subclass - SD50 - 5003 plate kitRN109.3
IgG Subclass COMBI kit - SDOne plate each of IgG1, IgG2, IgG3 and IgG44 plate kitRK021
IgA - NL545 - 54503 plate kitRN010.3
IgA - ML*8.5 - 853 plate kitRL010.3
nanorid- IgA - UL*0.43 - 4.33 plate kitGL010.3
IgA Subclass COMBI kit - NL

Two plates each of IgA1 and IgA2

IgA1 640 - 6400

IgA2 50 - 500

4 plate kitRK015
IgM - NL265 - 26503 plate kitRN012.3
nanorid- IgM - ML*7 - 703 plate kitGM012.3
nanorid- IgM - UL*0.35 - 3.53 plate kitGL012.3
IgG, IgA, IgM COMBI kit - NLOne plate each of IgG, IgA and IgM3 plate kitRK002
IgD - NL5 - 50 mg/L3 plate kitRN013.3
Kappa - Free and Bound - NL*1500 - 15000 mg/L3 plate kitRN015.3
Kappa Free - EL*20 - 2003 plate kitRE016.3
Lambda - Free and Bound - NL*825 - 8250#3 plate kitRN017.3
Lambda Free - EL*20 - 2003 plate kitRE018.3

# Diluted sample applied - assay range may be extended using undiluted sample.

Automated assays are also available for IgG and IgA Subclasses, IgD and free kappa and free lambda light chains.

Secretory IgA

IgA SecretoryThere are two populations of IgA, a monomeric form in serum, and a dimeric form found in secretions such as saliva, tears, bronchial fluids etc. The dimeric form is covalently associated with a J-chain and a secretory piece. This secretory IgA (SIgA) represents the first line of defence against micro-organisms on the mucosal surface. SIgA deficiency results in a lack of immunity to mucosal viruses. This RID kit has been developed to specifically recognise only the SIgA population and not it's component forms (monomeric IgA, J-chain etc).

DescriptionMeasuring Range (mg/L)PackCode
Secretory IgA - NL*45 - 4503 plate kitRN148.3

* Research use only

Human Coagulation Proteins

When a small blood vessel is injured, a series of reactions is initiated leading to the formation of a blood clot. This seals the vessel preventing further blood loss. Many of the clotting factors involved are enzymes which are activated during this cascade of events. There are three parts of the coagulation cascade; the intrinsic pathway, the extrinsic pathway and the common pathway. The end product of both the intrinsic, and the faster extrinsic pathway, is activated Factor X. This factor initiates a further cascade through the common pathway resulting in the formation of a stable fibrin clot at the site of injury.

Key factors in the clotting mechanism can be measured by Binding Site RID kits. These include Fibrinogen and Factor XIII, as well as protease inhibitors and anticoagulants that localise and limit the clotting process, for example anti-thrombin III (ATIII) and Protein C.

DescriptionMeasuring Range (mg/L)PackCode
Antithrombin III - NL50 - 5003 plate kitRN040.3
nanorid Factor XIII - NL*3 - 30#3 plate kitGT113.3
Fibrinogen - NL450 - 45003 plate kitRN056.3
Plasminogen - NL20 - 2003 plate kitRN065.3
nanorid Protein C0.5 - 5.03 plate kitGT118.3

# Diluted sample applied - assay range may be extended using undiluted sample.

* Research use only

Other Human Serum Protein RID kits

Radial immunodiffusion RID kits are available for laboratory detection of many other commonly measured human proteins, e.g. albumin.

DescriptionMeasuring Range (mg/L)PackCode
Albumin - NL5000 - 50000#3 plate kitRN032.3
Albumin - ML*16 - 1603 plate kitRL032.3
α1 - Antitrypsin - NL280 - 28003 plate kitRN034
nanorid β2 - Microglobulin - EL1 - 103 plate kitGT043.3
nanoridCRP - EL5.2 - 523 plate kitGT044.3
Caeruloplasmin - NL115 - 11503 plate kitRN045.3
Fibronectin - NL*50 - 5003 plate kitRN057.3
Haptoglobin - NL50 - 5003 plate kitRN058.3
nanorid Lysozyme - NL***1.5 - 153 plate kitGT073.3
Prealbumin - NL (Transthyretin)43 - 4303 plate kitRN066.3
Transferrin - NL440 - 44003 plate kitRN070.3

# Diluted sample applied - assay range may be extended using undiluted sample.

* Research use only

*** In the USA for research use only

For animal RID kits please download the Immunobiological Reagents Product Listing.

Measuring RID rings using Jeweller's Eye-PieceAccessories

The jeweller's eyepiece facilitates measurement of precipitin rings to the nearest 0.1mm using a graduated scale visible through the x8 magnification eyepiece.


The disposable precision bore calibrated micropipettes with a stainless steel plunger assembly are ideal for accurate pipetting of 1 - 5 μl volumes.

DescriptionPackCode
Digital RID Plate Reader1AD400
Jeweller's Eye-Piece1AD040

1-5µL Micropipette

plus 100 Disposable Capillaries

1AD041
RID Plates (unfilled)10IC003.1

BINDARID™ and NANORID™ are trademarks of The Binding Site Group Ltd., Birmingham, UK.